home *** CD-ROM | disk | FTP | other *** search
/ NetNews Offline 2 / NetNews Offline Volume 2.iso / news / comp / sys / amiga / hardware-part1 / 8478 < prev    next >
Encoding:
Internet Message Format  |  1996-08-05  |  1.0 KB

  1. Path: news.production.compuserve.com!news
  2. From: Oliver Kastl <100447.3361@CompuServe.COM>
  3. Newsgroups: comp.sys.amiga.hardware
  4. Subject: Re: Where is version 6.12 of Oktagon.device
  5. Date: 27 Mar 1996 23:25:31 GMT
  6. Organization: Elaborate Bytes
  7. Message-ID: <4jcipb$leu$1@mhafn.production.compuserve.com>
  8. References: <rmal.827933375@gen-off-3>
  9.  
  10. Hi Richard,
  11.  
  12. >> Any ideas on what it could be ? <<
  13.  
  14. Sorry, no idea. You can try disabling Reconnect for the Harddisk.
  15. Note: You should do this with the RDB block settings (using 
  16. HDInstTools or an equivalent), NOT OktagonPrefs. OktagonPrefs sets 
  17. the "default" behaviour for each SCSI-ID (e.g. Units without RDB 
  18. Block like Scanners, Streamers, CD-Roms). A valid RDB Block on any 
  19. Harddisk WILL override these settings for this Harddisk.
  20. You CAN temporary alter the settings with OktagonPrefs -> and then 
  21. click "USE".
  22. I am sorry if this is a bit confusing (settings all & everywhere) 
  23. but this is the way it is at the moment and is unlikely to change.
  24.  
  25. Hope this helps....
  26.  
  27. -- 
  28. Oliver Kastl, Elaborate Bytes
  29. Home is where the heart is
  30.